Specification:
Gas Detection & Sensors: Supports CH₄ (0–100%LEL, 1%LEL), O₂ (0–30%VOL, 0.1%VOL), CO (0–1000 µmol/mol, 1 µmol/mol), H₂S (0–100 µmol/mol, 1 µmol/mol); compatible with electrochemical, catalytic, semiconductor, PID, and infrared sensors.
Outputs & Relay: Two sets of relay outputs with contact capacity 30V DC 3A / 250V AC 3A.
Ports & Installation: Connection ports M20×1.5, G1/2; wall or pipeline mountable.
Operating Conditions: Humidity ≤95%RH (non-condensing), working pressure 86–106 kPa.
Explosion Proof & Protection: Ex db IIC T6 Gb / Extb IIC T80°C Db, IP66 rated for industrial safety.